4MFESW / Q-KYC SXM

Hardware & ops requirements

What you
need on the
other side.

Q-KYC SXM is the software. To run a regulator-grade deployment on it, you also need the right hardware, the right power-continuity, and the right backup architecture. These are the same controls a CBCS supervisor will ask for under NOIS art. 33 (5-year retention, intact records), LBP art. 14 (security measures), and CBCS P&G §6 / §9 (operational risk and business continuity).

Per-tier minimum spec

Three tiers,
three real budgets.

Same Q-KYC software underneath; the hardware scales with your client volume and continuity requirements.

Tier S

Sole practitioner · 1-5 staff · <10 active clients

Compute
i5 / Ryzen 5 desktop, Win 11 Pro
RAM
16 GB
Storage
512 GB NVMe + 1 TB USB SSD backup
UPS
APC Back-UPS 700VA (~5-8 min runtime)
Backup
3-2-1 — local USB + off-site cloud (Backblaze B2 / pCloud encrypted)
Off-site
~€60-120 / yr
RTO
< 4 hours
RPO
< 24 hours
Generator
not required

~€1,100

total external Yr 1 (hardware + backup)

~€100/yr Yr 2-5

Tier M

Small firm · 5-15 staff · 10-50 active clients

Compute
i7 / Ryzen 7 mini-tower, Win 11 Pro
RAM
32 GB
Storage
2× 1 TB NVMe mirror + 4 TB NAS
UPS
APC Smart-UPS C 1000VA (~30 min)
Backup
3-2-1 — NAS + off-site cloud
Off-site
~€150-300 / yr
RTO
< 2 hours
RPO
< 1 hour
Generator
optional (portable inverter ~€1,500)

~€2,400

total external Yr 1

~€250/yr Yr 2-5

Tier L

Mid DNFBP / TCSP · 15-50 staff · 50-500 clients

Compute
Server-grade Xeon / Ryzen Pro mini-tower
RAM
64 GB ECC
Storage
2× 2 TB NVMe enterprise RAID1 + 8 TB NAS
UPS
APC Smart-UPS SRT 2200VA online (~60 min)
Backup
3-2-1 + warm-DR option
Off-site
~€500-1,000 / yr
RTO
< 1 hour (with warm-DR: < 5 min)
RPO
< 1 hour
Generator
strongly recommended (~€3,500 standby diesel)

~€9,000-11,000

total external Yr 1 (with generator + warm-DR)

~€800-1,200/yr Yr 2-5

Compliance-driven controls

Why each line
is on the list.

Every hardware + ops requirement above ties to a specific statute citation. A CBCS supervisor's procurement-audit question — "why this spend?" — has a one-line answer in every case.

UPS + safe shutdown

Q-KYC's audit chain is hash-linked. PostgreSQL WAL keeps the chain mathematically intact across crashes, but only if the OS gets time to flush. Without a UPS, every power cut is a roll of the dice.

  • UPS triggers at 20% battery
  • PowerChute / NUT daemon sends graceful shutdown signal
  • Q-KYC-API service accepts SIGTERM, flushes pending audit events
  • PostgreSQL commits open transactions + flushes WAL
  • Total: < 60 seconds. UPS runtime must exceed this with margin.
CBCS P&G §6 · LBP art. 14

Backup: 3-2-1 rule

Three copies of the data, on two different media, with one off-site. The audit chain must be recoverable after a fire, theft, or hurricane.

  • Copy 1: live on the workstation/server
  • Copy 2: local backup (USB SSD / NAS)
  • Copy 3: off-site cloud (EU-resident provider)
  • Retention: 5 years per NOIS art. 33
  • Verification: verify_audit_chain.ps1 runs nightly on the off-site copy
NOIS art. 33 · LBP art. 14

Disaster recovery

A "calamity" in SXM context is most often a hurricane (annual risk) or extended grid failure. Q-KYC's recovery procedure restores the system to a known-good state from backup with verify_audit_chain.ps1 PASS before any new operations begin.

  • Tier S RTO: < 4 hours
  • Tier M RTO: < 2 hours
  • Tier L RTO: < 1 hour (warm-DR: < 5 min)
  • Annual DR test — restore to spare hardware, verify chain
  • Hurricane runbook — Tier L only; May + October dry runs
CBCS P&G §9 · NOIS art. 33

Encryption + physical security

Q-KYC encrypts documents at rest with Fernet (HKDF-derived key from COCAI_JWT_SECRET). Plus the OS itself should be encrypted, the room should be lockable, and the backup media should be physically separated from the live host.

  • BitLocker (Win 11 Pro) on the full disk
  • Fernet at rest via Q-KYC for the document corpus
  • Lockable cabinet for the server / workstation
  • NAS in adjacent room or fireproof safe (Tier L)
  • Off-site backup ≥ 100 km from live site
LBP art. 14 · CBCS P&G §6

Boundary of responsibility

What we ship.
What you bring.

A clear split keeps the audit trail clean: we are responsible for the software, you are responsible for the hardware it runs on. Both sides are documented + signed.

Q-KYC SXM provides
Customer provides
Q-KYC binaries, schema, screening connectors
Hardware per tier above
Bundled PostgreSQL 18 + schema + migrations
Windows 11 Pro / Server licence
Guidance + auto-shutdown hooks
UPS (S/M) or full standby with generator (L)
Sample backup scripts + audit-chain verifier
Backup target hardware + cloud subscription
DR runbook template + tested procedure
Annual DR test execution (we co-run during pilot)
Pilot-phase free regulator-meeting support
Office space + physical security

Procurement file ready

Download the
full spec PDF.

For your IT procurement, compliance officer, board approval, or auditor — the complete tier-by-tier breakdown with statute citations and EUR cost estimates. ~4 MB, English. Cite us if asked.